Kirloskar 320 KVA /Generator Set

185,000.00

In stock

         PRODUCT FEATURES

  • Low OPEX: Best in class fuel efficiency with O2E technology
  • Robust and Reliable Product: Lowest maintenance and trouble free product with Kirloskar Engines
  • Option of Air Cooled and Water Cooled Engines
  • Compliance: Latest Government Emission Norms CPCB II
  • Start Type: Controller Based Easy Push Start Type
  • Customer ServiceQuick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field)
  • Warranty: 2 years warranty & labour free onsite service under warranty period.

 

 

Estimated delivery time is 15 Days
Compare
Categories: ,

PRODUCT SPECIFICATION

Prime Rating at rated rpm (as per ISO8528 ) 1 kVA 320 HD 380 HD 400 HD 500 HD 600 HD 625 HD 750 HD 900 HD 1010 HD
kW 256 304 320 400 480 500 600 720 808
Genset Model KG1-320WS KG1-380WS KG1-400WS KG1-500WS KG1-600WS KG1-625WS KG1-750WS KG1-900WS KG1-1010WS
Frequency Hz 50 50 50 50 50 50 50 50 50
Power factor lagging 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Voltage (with Three Phase Supply ) V 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø 415 3Ø
Governing class (As per ISO 8528 Part-V) G3 G3 G3 G3 G3 G3 G3 G3 G3
Noise level dBA < 75 < 75 < 75 < 75 < 75 < 75 < 75 < 75 NA
Fuel Consumption* At 100 % Load Ltrs/hr 69 83.3 86.9 107.5 125.9 130.5 154 197 199
At 75 % Load 52.5 61.2 65.09 81.9 94.2 98.6 126.4 163 155
At 50 % Load 37.6 44.1 46 57.1 63.8 66.2 89.7 120 112
Fuel tank capacity Ltrs 850 850 850 990 990 990 990 990 990
Weight of genset with Dry Kg 5910 6000 6050 7200 7700 7800 8300 13600 13200
canopy (approx.)^
Overall dimensions of genset Length mm 5180 5446 5650 5650 6560 6560 6800 8000 7800
Width mm 2000 2000 2000 2000 2000 2000 2300 2300 2300
Height mm 2408 2408 2408 2558 2710 2710 2713 2713 2713
Electrical Battery starting voltage Volts-DC 24 24 24 24 24 24 24 24 24
ENGINE
Engine Model DV8TA G1 DV8TA G2 DV8TA G3 DV10TA G1 DV12TA G1 DV12TA G2 DV12ETA G11 DV16ETA G2 DV16ETA G1
Rated output (Prime Continuous rating as per ISO 3046) kW 294 346 360 447 532 552 663 799 889
HP 400 470 490 608 723 750 901 1086 1210
No. of cylinder Number 8 8 8 10 12 12 12 16 16
Cubic capacity 2 Ltrs 15.92 15.92 15.92 19.89 23.88 23.88 23.88 31.86 31.86
Bore x Stroke mm 130×150 130×150 130×150 130×150 130×150 130×150 130×150 130×150 130×150
Rated Speed RPM 1500 1500 1500 1500 1500 1500 1500 1500 1500
Aspiration NA/TC/TA TA TA TA TA TA TA TA TA TA
Lube Oil change period hrs 500 500 500 500 500 500 500 500 500
Lube Oil Sump Capacity Ltrs 105 115 115 120 145 145 145 205 205
ALTERNATOR
Insulation Class Class H Class H Class H Class H Class H Class H Class H Class H Class H
Ingression Protection IP 23 IP 23 IP 23 IP 23 IP 23 IP 23 IP 23 IP 23 IP 23
Alternator Efficiency (at 100% load) 0.8 pf** 94.3 93.3 93.4 94.6 95 95 94.6 95.3 95.1
Alternator Efficiency (at 75% load) 0.8 pf** 93.8 93.8 94 94.9 95.2 95.2 94.9 95.5 95.4
Permissible Voltage Dip at Full Load 0.8 pf Lag < 20 % < 20 % < 20 % < 20 % < 20 % < 20 % < 20 % < 20 % < 20 %
Time Permitted to build up rated voltage at rated RPM < 5 sec provided engine reach the rated speed
Short Circuit Withstand Time sec 3 Times Rated Current for “3 sec” 3 Times rated current for “10 sec “
Overload Withstand Capacity % 10% overload for one hour once in 12 hours